Kling-freitag K&F CD 44 Digital System controller User Manual Page 71

  • Download
  • Add to my manuals
  • Print
  • Page
    / 77
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 70
User's manual K&F CD 44 Digital System Controller
KLING & FREITAG GMBH © 2014 Version 11.6 Page 71 of 77
*Output1 / Out 1 as an example. Select the output which is connected to the speaker!
Prerequisite:
2 Subwoofer mit 2 tops
2 x CA 12012 x CA 106
2 x CA 1215
2 x CA 1515
2 tops
&
2 Subwoofer
2 x CA 1001
2 x Line 212
2 x SW 215E
2 x ACCESS B5
2 x ACCESS B10
2 x NOMOS XLC
2 x SEQUENZA 10 B
Output gain for
subwoofer*
Accessible with:
Output gain for
subwoofer*
Accessible with:
Switch off ‘Cluster’ (via Filter B) for tops and subwoofers* Accessible with:
*Output1 / Out 1 as an example. Select the output which is connected to the speaker!
12. Instructions for AES / EBU Data Transmission
12.1 General Instructions
The interface AES / EBU offers the possibility to transmit two digital audio channels via a
balanced cable. The sampling rate of the audio signal may be 32 kHz, 44.1 kHz, 48 kHz, 88.2
kHz, 96 kHz or 192 kHz with a resolution of max. 24 bits. The Kling & Freitag CD 44 System
Controller supports any type of sampling rates ranging from 44.1 kHz to 192 kHz with a
resolution of max. 24 bits.
When using the AES / EBU input, in addition to the system delay of 0.5 ms, a further delay
arises from the sample rate converter: With a sample rate of 44.1 kHz = approx. 2.4 ms. With
a sample rate 48 kHz = approx. 2.2 ms. With a sample rate 88.2 kHz = approx. 1.5 ms. With a
sample rate 96 kHz = approx. 1.4 ms.
As the handling of digital audio signals in practice differs from that of analogue signals, you
should observe the following suggestions in order to ensure dependable operations:
Page view 70
1 2 ... 66 67 68 69 70 71 72 73 74 75 76 77

Comments to this Manuals

No comments