Kling-freitag K&F CD 44 Digital System controller User Manual Page 16

  • Download
  • Add to my manuals
  • Print
  • Page
    / 77
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 15
User's manual K&F CD 44 Digital System Controller
KLING & FREITAG GMBH © 2014 Version 11.6 Page 16 of 77
20
50 100 500
1000
10000
20000
0
3
+6
Frequency in [Hz]
Power in [dB]
FilterType = 'Bell' (Bell Passband) Gain = +6dB Freq = 1000Hz
Q = 0.2
Q = 0.707
Q = 1.414
Q = 5
The gain determines the maximum or minimum level increase or attenuation of the filter
(in the graph: increase of +6dB.
This 'bell' is logarithmically symmetrical relative to the selected frequency (in the
example: 1000 Hz).
The Q-factor defines the quality of the filter. In doing so, it determines the width of the
frequency range which is to be increased or attenuated. The higher the Q-factor, the
narrower the frequency range. A lower Q-factor thus has a wider range.
"Q" is adjustable in steps of 0.001 from 0.2 to 20.
Typical Q-values and their bandwidth equivalent:
Bandwidth Q factor
1/3 Oktave (third) 4.318
2/3 Oktave (two thirds) 2.145
1 octave 1.414
1 1/3 1.044
1 2/3 0.819
2 0.666
1/6 octave (whole step) 8.651
2. HShelv (high shelving filter)
3. LShelv = Low Shelving Filter
These filters increase (positive gain) or attenuate (negative gain) the frequencies below
or above the selected frequency.
Below = LShelv
Above = HShelv